    Brand Name : DGBELL
    Model Number : BE-8202-2500/BE-8202-3000
    Certification : CE/ISO
    Price : Negotiation
    Payment Terms : T/T, Western Union, L/C, D/A, D/P, MoneyGram
    Supply Ability : 500 Sets per Month
    Delivery Time : Negotiation
    • Product Details
    • Company Profile

    UL 2580 PLC PC Control External Fire Test Machine for EV Battery Safety

    EV Battery Safety Tester External Fire Test Machine According to UL 2580


    External Fire Exposure Test Machine Standard

    • UL 2580

    Relative Standard test requirements

    1. Test Object: Battery pack and system.
    2. The test ambient temperature should be above 0 ℃, wind speed is not more than 2.5 km/h, and the SOC requirement of the battery pack is more than 50%.
    3. In the test, the size of the Flat plate with gasoline should exceed the horizontal size of the test object by 20 cm, no more than 50 cm. The height of the Flat plate should no more than 8 cm above the gasoline. The test object should be placed in the middle. The distance between the gasoline level and the test object is set to 50 cm. Inject water to the bottom of the Flat-plate before testing. The external burning diagram is shown in the graph.

    UL 2580 PLC PC Control External Fire Test Machine for EV Battery Safety

    • Test Phase 1: Preheat.

    Ignite the gasoline at least 3m away from the test object, and after 60 seconds of preheating, put the gasoline plate below the test device. If the gasoline flat plate size is too large to move, you can use the way of moving the test object and rack.

    • Test Phase 2: Direct burning.

    The test object is directly exposed to the flame for 70 seconds.

    • Test Phase 3: Indirect burning.

    Cover the gasoline plate with refractory baffles. Keep the test object in this condition for 60 seconds. Alternatively, by mutual consent, the test object continues to be exposed directly to the flame for another 60 seconds. The refractory baffles are made of standard refractory bricks. The sieve hole size is shown in the figure below. Refractory can also be made with reference to this size.

    UL 2580 PLC PC Control External Fire Test Machine for EV Battery Safety

    • Test Phase 4: Leave the fire source.

    Remove the gasoline plate or test object. Then observe for 2h or when the test object exterior temperature drops below 45°C.


    Technical Parameters

    Product Name


    External Fire Exposure Test Machine

    Model


    E-8202-2500BE-8202-3000

    Test Space


    W1500 X D2500 X H800mmW2000 X D3000 X H1000mm

    Equipment Dimension


    W7500 X D3700 X H960mmW8500 X D4200 X H960mm

    Movable Rack


    W1500 X D3000 mmW2200 X D3200 mm

    Max. Load


    1000KG (2000KG,3000KG can be customized)

    Object Holder Moving Speed


    6000mm/min (Adjustable)

    Refractory Rack Moving Speed


    6000mm/min (Adjustable)

    Control System


    PLC touch screen close control + computer remote control

    Ignition Mode


    Automatic high pressure pack ignition

    Distance Between Burning Plate and gasoline


    The distance between the gasoline and the test object can be adjusted within the range of 4 50cm~550mm. The defaulted 500mm; the bottom of the gasoline plate is filled with water.

    Refractory Brick Size


    In accordance with the standard of ECER100, Refractory Brick Size 240mm*120mm*70mm.

    Gasoline Plate Size


    3 gasoline plates-can be changed easily according to the test object size. the height of gasoline plate is no more than 80cm from the gasoline level

    Power Supply


    AC 380V,7.0KWAC 380V,8.0KW

    Weight


    Approx 3.5 TonsApprox 4.0 Tons
    Other requirements

    The ignition area of gasoline plate can be adjusted according to requirements.


    Automatic gasoline filling.


    Remote control.


    Electrical ignition according to test requirements.


    The video monitoring system, lighting system.